Installed molex connectors on fuel probe and fuel flow transducer and connected components to EMS harness and SkyView circuit breaker. Attached voltmeter input of EMS box to main bus bar. Ran firewall forward wires of EMS harness through gromet to engine compartment. Installed main display harness and hooked up power and ground connections. Connected SV-EMS-220 and SV-ARINC-429 boxes together with SV-NET-SPL and connected to main display. Temporarily installed screen and tested function.



Hours Worked: 1.57